Tektronix Passive High Voltage Probe P6015A: The Perfect Partner for Power Equipment Testing with Instruments
2024-11-21
Tektronix Passive High Voltage Probe P6015A
The Perfect Partner for Power Equipment Testing and Instruments
In the field of electronic measurement, high voltage probes are key tools to ensure measurement accuracy and safety. The passive high voltage probe series launched by Tektronix includes models such as P5100A, TPP0850, P5122, P5150 and P6015A, providing reliable solutions for various measurement requirements.

1. Product Overview
Tektronix passive high voltage probes cover a variety of models to meet the requirements of different oscilloscope series and measurement scenarios.
II. Product Features and Applications
1. P5100A
- Features: high-voltage probe for high-frequency applications, featuring low input capacitance and various screw-on accessories for convenient connection.
- Applications: commonly used in power supply design, motor drive and other fields.
2. TPP0850
- Features: It provides the highest bandwidth (800MHz) in the industry.
- Applications: It is suitable for testing power semiconductors and switching power supplies, can be used with high-voltage transistor switching circuits, and is also suitable for emerging power applications.
3. P5150 and P5122
- Features: When used with specific oscilloscope series, it achieves isolation between measurement and ground as well as between channels.
- Applications: P5150 is used for measuring high-voltage DC power ripple, while P5122 has usage limitations under specific conditions.
4. P6015A
- Features: It is an industry standard high voltage probe, with measurement up to 20kVRMS (DC) and 40kV (pulse). It adopts environment-friendly silicide dielectric and features a large compensation range.
- Applications: Widely used in scenarios with extremely high requirements for voltage measurement.
III. Technical Specifications Comparison
Probe | Nominal Length | Attenuation | Bandwidth | Rise Time (Typical) | Load Impedance | Maximum Input Voltage (DC or RMS) | Maximum Floating Voltage | Compensation Range (pF) | Reading |
P5100A | 2m | 100X | 500MHz | <700ps | 40MΩ/2.5pF | 2.5KV peak, 1,000VRMS CAT II | N/A | 7 to 30 | Yes |
TPP0850 | 1.3m | 50X | 800MHz | <525ps | 40MΩ/1.8pF | 2.5kV peak, 1,000VRMS CAT II | N/A | N/A | Yes |
P5122 | 1.2m | 100X | 200MHz | 2.2ns | 100MΩ/4.0pF | 1,000VRMS CAT II | 600VRMS CAT II | 10 to 22 | No |
P5150 | 2m | 50X | 500MHz | <700ps | 40MΩ/3.8pF | 2.5kV Peak, 1,000VRMS CAT II | 600VRMS CAT II, 300VRMS CAT III | 10 to 25 | No |
P6015A | 3m | 1000X | 75MHz | 4.0ns | 100MΩ/3pF | 20kV | Not applicable | 7 to 49 | No |
P6015A Option 1R | 3m | 1000X | 75MHz | 4.0ns | 100MΩ/3pF | 20kV | Not Applicable | 7 to 49 | Yes |
It can be seen from the comparison that P6015A has a significant advantage in maximum input voltage, capable of withstanding up to 20kVRMS (DC) and 40kV (pulse), which far exceeds other models. Meanwhile, its compensation range is also relatively larger.

IV. Application Fields
These probes are widely used in the following fields:
1. Fault diagnosis and maintenance of power systems.
2. R&D and production testing of electronic equipment.
3. Research and development in the new energy field.
V. Analysis of Advantages and Disadvantages
1. P5100A
- Advantages: low input capacitance, suitable for high-frequency measurement; multiple accessories for convenient connection.
- Disadvantage: relatively low maximum input voltage.
2. TPP0850
- Advantages: high bandwidth, suitable for emerging power applications.
- Disadvantage: relatively small attenuation ratio.
3. P5150 and P5122
- Advantages: Isolated measurement can be achieved when used with specific oscilloscopes.
- Disadvantages: P5122 has usage limitations under certain conditions.
4. P6015A
- Advantages: Ultra-high measurement voltage range and large compensation range.
- Disadvantages: Relatively low bandwidth.
6. Ordering Information and Accessories
1. P5100A/TPP0850 accessories include large hook tip, small hook tip, ground leads of different lengths, ground spring, alligator clip, etc.

2. P5122 accessories include large retractable hook tip, lead with hook tip, lead with alligator clip, adjustment tool, and user manual.

3. P5150 accessories are similar to those of P5100A/TPP0850, with additional commonly used springs and other parts.
4. P6015A accessories include hook tip, banana plug, alligator clip, ground wire, carrying case, and user manual.

In summary, each model of Tektronix passive high voltage probe series has its own characteristics. Users should make a comprehensive choice based on specific measurement requirements and application scenarios. With its ultra-high measurement voltage and large compensation range, P6015A has unique advantages in some applications that require extremely high voltage measurement performance.
We hope the above content helps you fully understand Tektronix passive high voltage probe series and provides a useful reference for your measurement work.
The above content is for reference only. You can adjust and modify it according to your actual requirements. If you have other questions or need further assistance, please feel free to contact us. Click here▶