Shenzhen Shijia Instruments Co., Ltd.

News

Bringing you the latest news, corporate culture, and product and technology insights from Shijia Instruments

Tektronix Passive High Voltage Probe P6015A: The Perfect Partner for Power Equipment Testing with Instruments

2024-11-21

Tektronix Passive High Voltage Probe P6015A

The Perfect Partner for Power Equipment Testing and Instruments

 

In the field of electronic measurement, high voltage probes are key tools to ensure measurement accuracy and safety. The passive high voltage probe series launched by Tektronix includes models such as P5100A, TPP0850, P5122, P5150 and P6015A, providing reliable solutions for various measurement requirements.

 

1. Product Overview

 

Tektronix passive high voltage probes cover a variety of models to meet the requirements of different oscilloscope series and measurement scenarios.

 

II. Product Features and Applications

 

1. P5100A

    - Features: high-voltage probe for high-frequency applications, featuring low input capacitance and various screw-on accessories for convenient connection.

    - Applications: commonly used in power supply design, motor drive and other fields.

 

2. TPP0850

    - Features: It provides the highest bandwidth (800MHz) in the industry.

    - Applications: It is suitable for testing power semiconductors and switching power supplies, can be used with high-voltage transistor switching circuits, and is also suitable for emerging power applications.

 

3. P5150 and P5122

    - Features: When used with specific oscilloscope series, it achieves isolation between measurement and ground as well as between channels.

    - Applications: P5150 is used for measuring high-voltage DC power ripple, while P5122 has usage limitations under specific conditions.

 

4. P6015A

    - Features: It is an industry standard high voltage probe, with measurement up to 20kVRMS (DC) and 40kV (pulse). It adopts environment-friendly silicide dielectric and features a large compensation range.

    - Applications: Widely used in scenarios with extremely high requirements for voltage measurement.

 

III. Technical Specifications Comparison

 

Probe

Nominal Length

Attenuation

Bandwidth

Rise Time (Typical)

Load Impedance

Maximum Input Voltage (DC or RMS)

Maximum Floating Voltage

Compensation Range (pF)

Reading

P5100A

2m

100X

500MHz

<700ps

40MΩ/2.5pF

2.5KV peak, 1,000VRMS CAT II

N/A

7 to 30

Yes

TPP0850

1.3m

50X

800MHz

<525ps

40MΩ/1.8pF

2.5kV peak, 1,000VRMS CAT II

N/A

N/A

Yes

P5122

1.2m

100X

200MHz

2.2ns

100MΩ/4.0pF

1,000VRMS CAT II

600VRMS CAT II

10 to 22

No

P5150

2m

50X

500MHz

<700ps

40MΩ/3.8pF

2.5kV Peak, 1,000VRMS CAT II

600VRMS CAT II, 300VRMS CAT III

10 to 25

No

P6015A

3m

1000X

75MHz

4.0ns

100MΩ/3pF

20kV

Not applicable

7 to 49

No

P6015A Option 1R

3m

1000X

75MHz

4.0ns

100MΩ/3pF

20kV

Not Applicable

7 to 49

Yes

 

It can be seen from the comparison that P6015A has a significant advantage in maximum input voltage, capable of withstanding up to 20kVRMS (DC) and 40kV (pulse), which far exceeds other models. Meanwhile, its compensation range is also relatively larger.

 

IV. Application Fields

 

These probes are widely used in the following fields:

 

1. Fault diagnosis and maintenance of power systems.

2. R&D and production testing of electronic equipment.

3. Research and development in the new energy field.

 

V. Analysis of Advantages and Disadvantages

 

1. P5100A

    - Advantages: low input capacitance, suitable for high-frequency measurement; multiple accessories for convenient connection.

    - Disadvantage: relatively low maximum input voltage.

 

2. TPP0850

    - Advantages: high bandwidth, suitable for emerging power applications.

    - Disadvantage: relatively small attenuation ratio.

 

3. P5150 and P5122

    - Advantages: Isolated measurement can be achieved when used with specific oscilloscopes.

    - Disadvantages: P5122 has usage limitations under certain conditions.

 

4. P6015A

    - Advantages: Ultra-high measurement voltage range and large compensation range.

    - Disadvantages: Relatively low bandwidth.

 

6. Ordering Information and Accessories

 

1. P5100A/TPP0850 accessories include large hook tip, small hook tip, ground leads of different lengths, ground spring, alligator clip, etc.

 

2. P5122 accessories include large retractable hook tip, lead with hook tip, lead with alligator clip, adjustment tool, and user manual.

 

3. P5150 accessories are similar to those of P5100A/TPP0850, with additional commonly used springs and other parts.

 

4. P6015A accessories include hook tip, banana plug, alligator clip, ground wire, carrying case, and user manual.

 

In summary, each model of Tektronix passive high voltage probe series has its own characteristics. Users should make a comprehensive choice based on specific measurement requirements and application scenarios. With its ultra-high measurement voltage and large compensation range, P6015A has unique advantages in some applications that require extremely high voltage measurement performance.

 

We hope the above content helps you fully understand Tektronix passive high voltage probe series and provides a useful reference for your measurement work.

 

The above content is for reference only. You can adjust and modify it according to your actual requirements. If you have other questions or need further assistance, please feel free to contact us. Click here▶