Shenzhen Shijia Instruments Co., Ltd.

Products

Specializing in spectrum analyzers, network analyzers, signal generators, LCR meters, oscilloscopes, power supplies, probes, digital multimeters, data acquisition systems, source measure units, power meters, battery testers, resistance testers and other high-frequency test instruments

E4980B / E4980BL Precision LCR Meter

  • ModelE4980B / E4980BL
  • AttributesPrecision LCR Meter
  • Category KEYSIGHT > LCR Meters & Impedance Measurement Products
  • BrandKEYSIGHT
  • DescriptionThe Keysight E4980B/E4980BL precision LCR meters cover a wide frequency range of 20 Hz to 2 MHz with 0.05% high accuracy, supporting capacitance, inductance, resistance, impedance and DC bias measurements, suitable for component testing and material analy

Detailed Introduction Technical Documents

Introduction


Keysight E4980B/E4980BL Precision LCR Meters deliver a wide frequency range from 20 Hz to 2 MHz (E4980B) or up to 1 MHz (E4980BL), with 0.05% basic accuracy, meeting various impedance measurement requirements from R&D to production lines.


Performance Features


Wide frequency range: 20 Hz to 2 MHz (E4980B) / 300 kHz/500 kHz/1 MHz (E4980BL)

Basic accuracy: 0.05% (typical)

Measured parameters: |Z|, |Y|, θ, L, C, R, G, D, Q, Vdc, Idc (Option 001)

Test signal level: Voltage 0 Vrms to 20 Vrms (Option 001), Current 0 Arms to 100 mArms

Automatic Level Control (ALC) function maintains constant test signal

List sweep: up to 201 points, primary/secondary parameter sweep

Comparator function: 9 bins, limit judgment

Built-in DC bias (Option 001 provides variable DC bias ±40 V / ±100 mA)

Multiple compensation: OPEN/SHORT/LOAD compensation

 

Applications

 

Characteristic testing of passive components (capacitors, inductors, resistors)

Impedance analysis of semiconductor devices (varactor diodes, LEDs, etc.)

Measurement of material dielectric constant and permeability

Internal resistance testing of power supplies and batteries

Automated sorting on production lines

 

Technical Specifications

Parameter

Specification

Frequency Range

E4980B: 20 Hz – 2 MHz
E4980BL-102: 20 Hz – 1 MHz
E4980BL-052: 20 Hz – 500 kHz
E4980BL-032: 20 Hz – 300 kHz

Frequency Resolution

0.01 Hz (20–99.99 Hz) to 1 kHz (1–2 MHz)

Measurement Parameters

Cp, Cs, Lp, Ls, R, X, Z, Y, G, B, D, Q, θ, Vdc, Idc (Option 001)

Equivalent Circuit

Series/Parallel

Test Signal Voltage

0 Vrms – 2 Vrms (Standard) / 0 – 20 Vrms (Option 001)

Test Signal Current

0 Arms – 20 mArms (Standard) / 0 – 100 mArms (Option 001)

Basic Accuracy

0.05% (typical)

Impedance Display Range

Z, R, X: 1 aΩ – 999.9999 EΩ
C: 1 aF – 999.9999 EF
L: 1 aH – 999.9999 EH
D: 0.000001 – 9.999999
Q: 0.01 – 99999.99

Measurement Speed

Short mode: 5.6 ms (2 MHz) to 330 ms (20 Hz)
Medium/Long mode: 88 ms to 480 ms

Trigger Delay

0 – 999 s, 100 μs resolution

Averaging

1 – 256 times


Accessories


Included Standard:

Power cord, user manual, calibration certificate, USB cable


Options:

16048A/D/E Test Cable (0/1/2/4 m)

Test Fixture (Keysight 16047E, 16034G, etc.)

Option 001: Power and DC Bias Enhancement (20 Vrms, ±40 Vdc, ±100 mAdc)

Option 201: Handler Interface

Option 301: Scanner Interface

Option 710: No Interface

 


Interfaces


Included Standard:

GPIB (IEEE488.1/2, SCPI), USB (USBTMC-USB488), LAN (10/100 BaseT, LXI Class C), USB Host (USB flash storage)


Options:

Handler Interface (Option 201), Scanner Interface (Option 301)


Physical Specifications

 

Dimensions (W×H×D): 375 mm × 105 mm × 390 mm (including handle and corner guards) / 336 mm × 85 mm × 336 mm (excluding)


Weight: 4.9 kg (excluding corner guards and handle) / 5.8 kg (including)