Shenzhen Shijia Instruments Co., Ltd.

Products

Specializing in spectrum analyzers, network analyzers, signal generators, LCR meters, oscilloscopes, power supplies, probes, digital multimeters, data acquisition systems, source measure units, power meters, battery testers, resistance testers and other high-frequency test instruments

E4980A / E4980AL Precision LCR Meter

  • ModelE4980A / E4980AL
  • AttributesLCR Meter
  • Category KEYSIGHT > LCR Meters & Impedance Measurement Products
  • BrandKEYSIGHT
  • DescriptionThe Keysight E4980A/E4980AL precision LCR meters cover 20 Hz to 2 MHz with 0.05% basic accuracy, supporting measurement parameters such as L/C/R/Z/Y/D/Q/θ/Rdc/Vdc/Idc. They feature built-in open, short and load compensation, come standard with GPIB, LAN a

Detailed Introduction Technical Documents

Introduction

Keysight E4980A/E4980AL Precision LCR Meter provides broadband measurement from 20 Hz to 2 MHz, with 0.05% basic accuracy, suitable for high-precision impedance testing of components and materials.


Key Features

Frequency Range: 20 Hz to 2 MHz (E4980A), 20 Hz to 1 MHz / 500 kHz / 300 kHz (E4980AL)

Basic Accuracy: 0.05% (typical, MED/LONG mode)

Test Signal Level: 0 Vrms to 2 Vrms (standard); Option 001 extends to 20 Vrms / 100 mArms

DC Bias: 0 V / 1.5 V / 2 V standard; Option 001 provides -40 V to +40 V / -100 mA to +100 mA

Measurement Parameters: L、C、R、Z、Y、D、Q、θ、Rdc、Vdc、Idc

Measurement Speed: Up to 5.6 ms/point (SHORT mode, 2 MHz)

Compensation Functions: Open-circuit, Short-circuit and Load Compensation


Applications

Passive components (capacitors, inductors, resistors), semiconductor devices, dielectric/magnetic materials, printed circuit board impedance analysis, production testing, quality inspection.


Technical Specifications

Parameter

Specification

Frequency Range

20 Hz – 2 MHz (E4980A)
20 Hz – 1 MHz / 500 kHz / 300 kHz (E4980AL)

Frequency Resolution

0.01 Hz (20–99.99 Hz) ~ 1 kHz (1–2 MHz)

Basic Accuracy

0.05% (typical, MED/LONG mode)

Measurement Parameters

Cp-D, Cp-Q, Cp-G, Cp-Rp; Cs-D, Cs-Q, Cs-Rs; Lp-D, Lp-Q, Lp-G, Lp-Rp, Lp-Rdc; Ls-D, Ls-Q, Ls-Rs, Ls-Rdc; R-X, Z-θ, G-B, Y-θ, Vdc, Idc

Display Range

C/L: ±1 aF to ±999.9999 EF
D: 0.000001 ~ 9.999999
Q: 0.01 ~ 99999.99
R/X/Z: ±1 aΩ to ±999.9999 EΩ
G/B/Y: ±1 aS to ±999.9999 ES
θ: ±0.0001° ~ 180.0000°
Δ%: ±0.0001% ~ 999.9999%

Test Signal Voltage

0 – 2 Vrms (resolution starting from 100 μVrms)
Option 001: 0 – 20 Vrms (≤1 MHz)

Test Signal Current

0 – 20 mArms (resolution 1 μArms)
Option 001: 0 – 100 mArms

Output Impedance

100 Ω (nominal)

Measurement Time Mode

SHORT / MED / LONG

Number of Averages

1 – 256

Trigger Delay

0 – 999 s


Accessories

 

Standard Accessories:

Power Cord, Quick Start Guide, Calibration Certificate

 

Options:

Option 001: Enhanced Power and DC Bias (20 Vrms / ±40 V / ±100 mA)

Option 200: DCR Measurement

Option 201: Handler Interface

Option 301: Scanner Interface

Frequency Option: E4980AL-032/052/102

Test Cables: Keysight 16048A/D/E (1/2/4 m)

 

Interfaces

Standard: GPIB, LAN, USB (Host Type A + Device Type Mini-B)

Options: Handler Interface (201), Scanner Interface (301)

 

Physical Specifications

Dimensions: 375 mm (Width) × 105 mm (Height) × 390 mm (Depth) (nominal, with handle and bumper)

Weight: 5.3 kg (nominal)