P6015A High-Voltage Probe

  • ModelP6015A
  • AttributesHigh-Voltage Probe
  • Category TEKTRONIX > High-Voltage Probe
  • BrandTEKTRONIX
  • DescriptionThe P6015A uses an environmentally friendly silicone dielectric that never needs refilling. Additional features include a 7-49 pF compensation range, a compact compensation box suitable for adjacent amplifier inputs, and a readout for most Tektronix digit

Detailed Introduction Technical Documents

Features and Benefits

P5100A
  • DC to 500 MHz

  • 2500 VPeak, 1000 VRMS CAT II

  • 100X, with probe head coding

  • UL3111-1、EN61010-1、IEC61010-2-031、CSA1010.1、CSA1010.2.031

  • 7 ~ 30 pF compensation range

TPP0850
  • DC to 800 MHz

  • 2500 VPeak, 1000 VRMS CAT II

  • 50X, with probe head coding

  • Designed for MSO/DPO5000 and MSO/DPO4000B Series Oscilloscopes

P5122
  • For TPS2000 and THS3000 Series Oscilloscopes

  • DC to 200 MHz

  • In DC coupling, 1000 VRMS CAT II*1

  • Floating up to 600 VRMS CAT II

  • 100X

  • IEC61010-031

P5150
  • For TPS2000 and THS3000 Series Oscilloscopes

  • DC to 500 MHz

  • 2500 Vpeak, 1000 VRMS CAT II

  • Floats up to 600 VRMS CAT II or 300 VRMS CAT III

  • Probe for ripple measurement

  • 50X

  • 10 ~ 25 pF Compensation Range

  • UL61010B-2-031、EN61010-2-031、IEC61010-2-031、CSA61010.2.031

P6015A
  • High Voltage – 20 kV DC/40 kV peak (100 ms pulse width)

  • High Bandwidth – DC to 75 MHz

  • Silicone dielectric

  • Optional 1000X with header coding

  • Wide compensation range (7 ~ 49 pF)

  • Large-capacity multi-functional ground lead and alligator clip

Applications

  • Power supply design

  • Motor drive design

  • Electronic ballasts

  • Power semiconductors

  • Switch mode control

  • UPS systems

  • Power rectifiers

*1 The P5122 probe cannot perform AC coupling measurement on signals with DC bias exceeding 300 V when used with TPS2000 series oscilloscopes. P5150 probe is recommended when measuring ripple of high-voltage DC power supplies.

P5100A High Voltage Probe

P5100A is a 2.5 kV high voltage probe for high frequency applications with low input capacitance. After probe compensation, it can be used with plug-ins and oscilloscopes with a nominal input capacitance of 7-30 pF. Various screw-on accessories facilitate connection to devices under test.

TPP0850 High Voltage Probe


TPP0850
 

TPP0850 is an ultra-high bandwidth (800 MHz) probe for high voltage signals up to 2500 Vp-p. It offers the ideal bandwidth for testing power semiconductors and switching power supplies. Minimizing power loss by increasing switching speed requires probes with faster rise time, higher bandwidth and higher voltage rating, and TPP0850 meets this need perfectly. It can be used with transistor switching circuits operating at 1200 VRMS , which exceeds the operating voltage range of standard general-purpose probes. It is also suitable for emerging power applications that require faster rise time.

Applications of P5150 and P5122 IsolatedChannel™

In many applications, it is critical to isolate measurements from ground and isolate common voltage between channels. When used with TPS2000 and THS3000 series digital storage oscilloscopes, P5150 or P5122 achieves isolation between measurement and ground, as well as complete isolation between channels. The P5150 probe is recommended for measuring ripple of high-voltage DC power supplies. The P5122 probe must not be used for AC coupling measurement of signals with DC bias exceeding 300 V on TPS2000 series oscilloscopes.

P6015A High Voltage Probe

For high-capacity, high-performance voltage measurement above 2.5 kV, the P6015A has become an industry standard. It can measure DC voltages up to 20 kVRMS and pulse voltages up to 40 kV (peak value, 100 ms pulse width). The 75 MHz bandwidth allows you to capture fast high-voltage signals.

The P6015A uses environmentally friendly silicide dielectric that requires no refilling. Additional features include: a compensation range of 7-49 pF, a compact compensation box suitable for adjacent amplifier inputs, and a readout head compatible with most Tektronix digital oscilloscopes. When using the readout head, the displayed voltage amplitude is the actual signal value, and no conversion by a factor of 1000 is required.