Tektronix 5 Series B MSO Mixed Signal Oscilloscopes: Performance Upgrades and Innovative Applications
2024-11-25
Tektronix 5 Series B MSO Mixed Signal Oscilloscope
MSO54B MSO56B MSO58B
Performance Upgrades and Innovative Applications
In the field of electronic measurement, Tektronix has been leading the industry development with its outstanding technology and innovative products. As a new-generation product from Tektronix, the 5 Series B MSO Mixed Signal Oscilloscope inherits the excellent features of the previous generation, and delivers a series of performance upgrades and functional innovations, providing engineers and researchers with more powerful and more convenient measurement solutions.
1. Product Overview
The 5 Series B MSO Mixed Signal Oscilloscope offers three models: MSO54B, MSO56B and MSO58B, with 4, 6 and 8 FlexChannel inputs(flexible channel input) respectively. Users can flexibly configure them as analog signal inputs or digital logic inputs according to actual requirements.
It is equipped with a 15.6-inch high-definition capacitive touchscreen,
The resolution is up to 1920x1080, delivering users a clear and intuitive operating experience.
II. Main Performance Features
1. High Resolution and High Sampling Rate
- It adopts a 12-bit ADC, which can reach up to 16 bits in high-resolution mode, enabling fine capture and accurate measurement of signals.
- The real-time sampling rate is up to 6.25 GS/s, and the interpolation sampling rate reaches 500 GS/s, ensuring that fast-changing signals can also be acquired accurately.
2. Large Record Length
- It is standard-equipped with a record length of 62.5M points, and users can also opt for 125M, 250M or 500M points, which facilitates the analysis and research of long-duration signals.
3. Rich Trigger Functions
- Supports multiple trigger types including edge, pulse width, runt and more, plus an exclusive visual trigger function to help users easily capture key events in complex signals.
4. Powerful Spectrum Analysis
- Equipped with standard spectrum view and integrated RF measurement, allowing simultaneous observation of time domain and frequency domain views for more comprehensive and in-depth signal analysis.

III. Analysis Functions
1. Basic Waveform Analysis
- Provides 36 types of automatic measurements covering key parameters including amplitude, timing, jitter and more, meeting all conventional measurement requirements.
2. Protocol Decode and Analysis
- Supports triggering, decoding and analysis for multiple serial bus protocols, facilitating in-depth interpretation of digital communication signals.
3. Template and Limit Testing
- It is used to verify certain signal behaviors in the verification system to ensure that the system performance meets expectations.
4. User-Defined Filtering
- Users can specify any filter via MATH function to implement personalized processing and analysis of signals.
IV. Accessory Advantages
| Accessories | Details |
|---|---|
| Standard Probe | One 10MΩ passive voltage probe per channel |
| Standard Accessories | Various adapters, test probes, ground wires, etc. |
| Optional Accessories | Arbitrary/Function Generators, Digital Multimeters, Trigger Frequency Counters, TekDrive, etc. |
5. Connection and Communication
The 5 Series B MSO Mixed Signal Oscilloscope is equipped with a rich set of interfaces, including USB Host, USB Device, LAN, DisplayPort, DVI-D, VGA and more, enabling convenient data transmission and interaction with other devices. It also comes standard with the e*Scope function, which allows remote control via network connection to improve work efficiency and convenience.
VI. Differences Compared with 5 Series MSO
| Comparison Item | 5 Series B MSO | 5 Series MSO |
|---|---|---|
| New Features | Added auxiliary trigger input, built-in function generator waveform speed is doubled, brighter display, added history mode, new processor for more responsive control, new solid-state drive system for enhanced security | None |
| Unchanged Features | Directly replaceable, with the same award-winning user interface, industry-leading passive probes provided free of charge, ATE system programming interface, probe compatibility, dimensions, rack requirements and software solutions, compatible with the same floating software license, with the same noise performance, sampling rate, record length and bandwidth options | / |
7. Advantages and Disadvantages Analysis
1. Advantages
- High resolution and sampling rate, which ensures measurement accuracy and precision.
- Rich functions and analysis options to meet various complex measurement requirements.
- Flexible input configuration and large record length to adapt to test scenarios of different scales.
- High-quality display and user-friendly operation interface to improve user experience.
2. Disadvantages
- Relatively high performance leads to relatively high price, which brings certain pressure to users with limited budget.
8. Application Fields
The 5 Series B MSO mixed signal oscilloscopes are widely used in the following fields:
1. Electronic Circuit Design and Debugging
- It helps engineers accurately measure and analyze signals during circuit development, and quickly locate and solve problems.
2. Communication System Testing
- Conduct comprehensive evaluation on the quality, spectral characteristics and protocol of communication signals.
3. Automotive Electronics R&D
- Used for performance testing and fault diagnosis of automotive electronic systems.
4. Industrial Automation Control
- Monitor and analyze signals in industrial control systems to ensure stable system operation.
Tektronix 5 Series B MSO mixed signal oscilloscopes, with their excellent performance, rich functions and innovative design, demonstrate strong competitiveness in the field of electronic measurement. Whether in R&D laboratories or production sites, it provides users with reliable and efficient measurement solutions.
The above content is for reference only. If you have any other questions or need further assistance, please feel free to contact us.Click here▶